Simulation Studies and Control of Membrane Vibration in Air Sampling Pumps

Authors

  • Bui Dang Thanh Hanoi University of Science and Technology
  • Khánh Dương Trần
  • Quang Địch Nguyễn
  • Văn Trường Vũ

Keywords:

Amplitude, Membrane, PID, Sampling pump, Vibration

Abstract

The manuscript presents numerical results of the vibrations of the membrane of a low-power sampling pump for quality assurance of air around industrial parks. We consider a three-dimensional membrane undergoing the influences of its materials and vibration amplitudes. Four materials are used to investigate with the membrane’s amplitude varied in the range of 2-8 mm. The results provide an optimal option for the selected pump. Moreover, we also introduce a PID controller for this pump.

Downloads

Download data is not yet available.

Published

06-06-2022

How to Cite

Bùi, Đăng T., Trần, K. D., Nguyễn, Q. Địch, & Vũ, V. T. (2022). Simulation Studies and Control of Membrane Vibration in Air Sampling Pumps. Journal of Measurement, Control, and Automation, 3(1), 10-16. Retrieved from https://mca-journal.org/index.php/mca/article/view/73